|
|
|
|
Marquette Mac 1200 Resting ECG
|
| Selected Ad |
| Category: |
Patient Monitors |
| Title: |
Marquette Mac 1200 Resting ECG |
| Ad
Number: |
1556 |
| Date Posted: |
2/3/2005 |
| Contact: |
Justin Jeffries
1800 Williamson Court Louisville, KY 40223
|
| Telephone: |
502-244-4444
|
| Website: |
http://www.dremed.com
|
|
|
|
|
|
Description
Call: 1-800-462-8195 The GE Marquette MAC 1200 Resting ECG Analysis System is a comprehensive solution with practical features clinicians at smaller hospitals, clinics and physician offices will appreciate. The MAC 1200 is a compact 12-lead electrocardiograph designed for acquisition with or without analysis. The system can be configured as a standard electrocardiograph without analysis for facilities with minimal ECG requirements. The system can also be configured to incorporate the 12SL ECG analysis program. Adding the 12SL program creates an electrocardiograph with the industry leading interpretation program and measurements. This refurbished MAC 1200 Basic includes: Interpretive Electrocardiograph with 12-lead analysis, Waveform Display, Full-sized paper format, Alphanumeric keypad, patient cable, paper, power cord. Features Overview Comprehensive solution for ECG requirements. Waveform LCD display. Interpretive EKG. Full size paper reports. Portable with built-in battery. Measurements, interpretation and memory available in any combination. Simultaneous 12-lead ECG acquisition and analysis. Compact, lightweight design with carrying handle. Field upgradability. TECHNICAL SPECIFICATIONS Provides 10 seconds of instantaneous ECG acquisition and printing of any selected report format. Microcomputer-controlled 12 lead resting ECG system.Signal Processing Acquisition: 12 leads - simultaneously Signal input: Type CF according to IEC Digital sampling rate: 1000 samples/second/channel Dynamic range: Differential signals for AC voltage �, 10mV Superimposed DC voltage (Polarization voltage) �600mV Resolution: 5 uV Frequency response:0.04 - 150 Hz Common mode rejection:> 140 dB Input impedance: > 100 M ohms Leakage current: < 10uA Pacemaker detection sensitivity: All leads, duration 0.1 - 2.5 ms, amplitude > 5 mV Display Type:LCD 320 x 240 pixel, backlit, Contrast adjustable Displayed data: Selected lead group, operation mode, lead check, heart rate, AC filter, muscle her, ADS, gain, speed, name, ID, 3 ECG waveforms. Writier Type: Thermal array print head Resolution: Vertically 8 dots/mm horizontally 25um at 25 mm/s Paper: 8.5 x 11 inch Writer speed: 5, 25, 50 mm/s Paper type: Z-fold Keyboard Type: Membrane keypad with tactile feedback / 46 keys Special Functions Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the eletrodes. Baseline adjustment: ECG presentation on averaged baseline. Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Each single electrode is monitored. Copy: In the automatic 12 lead mode , after ECG, recording, copies of the ECG can be printed. Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input. Power Supply Ratings: 10 - 120 V (0.32A) / 220 - 240 V (0.16A) Frequency: 49 - 65 Hz Battery type: NiCad, 18V, 1.4 Ah Battery charge time: 4 hours Physical Specs Width: 14.5 in (370 mm) Height: 3.7 in (94 mm) Depth: 12.6 in (320 mm) Weight: 12.4 lb. (5.6 kg) with graphics display and battery
Click here for more info... |
|
|
|
|
|
|